<LOGO>
FM Transmitter Measurement Report
Created: 2024-07-30 23-10-08
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 57 dBuV SANDELS
Pilot RDS Phase Difference
6.6 kHz 6.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
15 kHz 62 kHz 15080 4,7016
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,6 dBr 2,89 dBr 4,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 62 kHz MIN: 15 kHz % above 76 kHz: 4,7016 Acquired: 2024/07/30 23.09.04 Total samples: 15080 Equivalent time: 0:12:34 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400